Remove The Moisture

Advantages of MagnaDRY® Technology

TempMaster has a complete hot gas dehumidification product offering from 3 to 12.5-tons.  MagnaDRY units have the ability to provide the temperature and humidity levels you need with a simple, competitive, energy efficient and reliable design.  The TempMaster MagnaDRY system combines a high efficiency heating/cooling unit with a “state-of-the-art” dehumidification system to:

  • Provide superior dehumidification at wide range of OD temperatures
  • Provides comfort by providing cooling and/or dehumidification when needed
  • Does not overcool the space
  • Reduce refrigerant transient time to less than 30 seconds with the MagnaDRY design
  • Achieve steady state capacity and efficiency very quickly (competition up to 1 hr or longer)

For many facility owners, a conventional air-conditioning system creates a dilemma – you either get the temperature or the humidity level you want, but not both.  TempMaster now has a solution to this situation. The MagnaDRY system from TempMaster uses proven technology to provide the temperature and humidity levels concurrently in one energy-efficient design.

Try to imagine the conditions of a cave.  Cold and damp. A cave may be a nice place to visit, however, you would not want to live there.  Neither would your customers. Conventional air conditioning systems are not designed to handle conditions when the temperature is moderate, but the humidity is high.  In these cave-like conditions, users have only two options, and neither of them are good. They can either endure uncomfortably high humidity levels with a moderate room temperature, or they can lower the humidity level with the unwanted side effect of the space getting too cold.

The MagnaDRY Series units provide the answer for both issues.  Instead of either-or, now you can meet temperature and humidity requirements with the MagnaDRY reheat series packaged units.  Superior to conventional air-conditioning dehumidification, MagnaDRY units remove moisture and use a reheat mode of operation that doesn’t rely on expensive electric heat or natural gas.  Because MagnaDRY can remove moisture without increasing sensible cooling, you can maintain temperatures and humidity within the comfort zone without significant added energy cost.

Conventional dehumidification systems reheat with natural gas or electricity, methods that aren’t acceptable under ASHRAE 90.1 energy standards.  But thanks to innovative dehumidification technology, the MagnaDRY design meets the ASHRAE 90.1 energy standard. It’s the one specification that solves the temperature/humidity problem with an efficient, energy-saving design for a wide range of applications.

 

APPLICATION & SITUATION

Supermarket:  Cold case door fogs up when a customer opens the display door.  A customer cannot see the food behind the door. The negative impact to sales is similar to what would be experienced if curtains were hung in front of all the items in the canned goods isles.  Grocery store patrons will not buy what they cannot see. Additionally, the customer may keep the door open while making a buying decision, which wastes energy. In either event, the customer could limit their time in the frozen food section, resulting in lower frozen food sales.

Dentist/Doctor’s Office:  Often times a large number of patients are in a small waiting room and it is creating uncomfortable high humidity levels and possibly causing window condensation and creating an atmosphere conducive to mold growth. The patients become irritable, and this only increases the tension in a room full of people who would rather be somewhere else.  This ultimately makes the doctor or dentist’s job more challenging when dealing with irritable patients. The only solution the doctor/dentist has is to turn up the air conditioning, thereby decreasing the room temperature.

Printing Facility:  Production lines slow down because the high humidity levels are causing the paper to stick together.  The high humidity levels may prevent the ink on the paper from drying properly reducing the quality of the print.  Downtime or reprinting is very expensive.

Art Gallery/Museum:  A curator may be concerned that high humidity levels will damage valuable artwork, artifacts, and other valuable objects that may be sensitive to high humidity levels.  The Art Gallery/Museum has a lot of money at risk and the humidity levels, with comfortable temperatures, are vital to the success of that establishment.

Fitness/Recreation Center:  Excess humidity caused by body heat is causing the front windows and mirrors to fog up.  Odor levels, mold, and bacteria growth increase with the increase in humidity, which makes for a very uncomfortable and uninviting place for patrons to work out.  This may decrease the participation at the fitness/recreation center.

Locker Room:  Showers and saunas increase humidity levels as well as create a damp feeling in the locker room.  These hot, humid, and damp conditions are also perfect for mold and bacteria growth. Mirrors will also fog if the humidity levels are not dealt with properly.  Patrons may find it hard to completely dry off before putting on their street clothes.

Food Production Line:  An owner may have trouble with dry food products clumping in machinery due to high humidity levels.  A donut production line applying glazing to the donut may have trouble packaging the donuts if the glazing does not dry properly.  High humidity levels could also promote or increase mold or bacteria growth in food production facilities. This can be a costly problem that would be difficult for a conventional RTU to handle effectively.

Banquet Halls/Buffets:  Restaurant owners may have problems with windows fogging due to excessive moisture levels from open food containers and high occupancy loads.  Food odors may also linger, which negatively impact the customers experience at the facility.

Laundromat:  The combination of heat and moisture from washer and dryers can cause the room to feel muggy and uncomfortable.  High or uncontrolled humidity levels can also cause window and mirrors to fog.

Pharmaceutical Company:  Production managers can have a difficult time keeping drug ingredients dry without overcooling.  If production workers are cold, it could have an adverse effect on worker performance.

 

Technological Advantages with the 3 to 5-Ton MagnaDRY System:

Figure 1: Cooling Mode

Normal cooling operation occurs when discharge gas from the compressor is routed to condensing coils 1 & 2 located in the outdoor condensing section. Compressor discharge gas is condensed to a liquid in the outdoor condensing section and then continues in the system to the TXV (Thermostatic Expansion Valve). As the high pressure liquid goes through the thermostatic expansion valve, the refrigerant is reduced to a low temperature, low pressure gas/liquid. The cool evaporator temperature causes the air forced across the evaporator to a lower temperature/humidity providing a cooling effect . Refrigerant Recovery Valve #2 (Sol 2) is closed during cooling operation to avoid short circuiting condenser coil #2. Refrigerant Recovery Valve #1  (Sol 1) on the reheat coil is opened to allow the refrigerant in the reheat coil circuit to return to the active system. The refrigerant recovery valves may be cycled to maintain refrigerant charge.

Figure 2: Reheat Mode

Reheat operation occurs when compressor discharge gas is routed through the reheat coil which is positioned directly downstream of the evaporator coil. When a call for reheat occurs, the 3 -Way Valve (Sol 3) diverts compressor hot gas to the reheat coil while condensing coil 1 and the reheat coil are active and the condensing coil 2 is inactive. Note: condensing coil 1 and condensing coil 2 are of equal size and volume. The reheat coil is approximately equal in volume to condenser coil 2. Refrigerant Recovery Valve #2 (Sol 2) is opened allowing refrigerant to return to the active system. Refrigerant Recovery Valve #1 (Sol 1) is closed to eliminate short circuiting during reheat operation. In each mode of operation a condenser fan motor speed control is used to control the compressor discharge pressure. The refrigerant recovery valves may be cycled to maintain refrigerant charge.

 

Technological Advantages with the 6.5 to 12.5-Ton MagnaDRY System:

Figure 3: Cooling Mode

Figure 3 shows the piping diagram and refrigerant flow in the cooling mode for the 6.5 to 12.5-ton MagnaDRY units.  The 6.5 to 12.5-ton units use an evaporator coil, one reheat coil, and one condenser coil and are designed to operate in conjunction with separate AC only cooling system within the same unit.  In the cooling mode, solenoid valve #1 opens, and solenoid valve #2 closes. Refrigerant flows from the evaporator coil to the compressor as a low temperature, low pressure vapor. After the compressor, the refrigerant becomes a high pressure, high temperature vapor and flows through the condenser coil. The refrigerant condenses back into a high pressure liquid and flows through the txv valve.  The txv valve allows the refrigerant to flash into a low pressure, low temperature refrigerant as it moves into the evaporator coil. Where the cycle is repeated.

Figure 4: Reheat Mode

Figure 4 shows the piping diagram and refrigerant flow in the reheat mode for the 6.5 to 12.5-ton MagnaDRY unit.  In the reheat mode, solenoid valve #1 closes, solenoid valve #2 opens. Refrigerant from the condenser coil flows back through solenoid #2, through the accumulator to the compressor.  The reheat valve switches positions and the refrigerant, as a high pressure, high temperature vapor flows through the reheat coil. The reheat coil now acts as the condenser coil. The refrigerant now flows through the check valve and txv valve.  The txv valve allows the low temperature, high pressure liquid to flash into a low pressure, low temperature vapor as it enters the evaporator coil. The change from cooling mode to reheat mode takes only a matter of seconds.